N84 Grid

Berkswell 275kV Substation

NESO connection site, host NGET.

Contracted here0.35 GWNot yet connected, as printed
Entries in the queue3entries with a printed MW
Earliest connection date31 Oct 2027Date printed in the register

The queue, in order

Order calculated by N84
First in queue349.4 MW across the first 3 projects
Order calculated by N84: printed queue position where the register gives one; otherwise entries printed as Gate 2 first, then every other entry by connection date. The register prints no gate for many contracted entries; N84 does not guess their position. Not published by the operator.

Dates in the queue

From the earliest date we hold to the connection date printed, in queue order

Order calculated by N84: printed queue position where the register gives one; otherwise entries printed as Gate 2 first, then every other entry by connection date. The register prints no gate for many contracted entries; N84 does not guess their position. Not published by the operator. Start is the accepted date as printed, else the date N84 first saw the row.
Table view
Dates in the queue
ProjectFromConnection dateMW
Berkswell Energy Storage31 May 202431 Oct 2027200 MW
Berkswell (Tertiary)31 May 202430 May 202857 MW
012 NEP Coventry West31 May 202431 Oct 203492.4 MW

Contracted MW as dates arrive

Running total by connection year, years to scale

0 MW200 MW400 MW2027: 200 MW2028: 257 MW2034: 349 MW20272028202920302031203220332034349 MW
0 MW200 MW400 MW2027: 200 MW2028: 257 MW2034: 349 MW2027202920312034349 MW
Order calculated by N84: printed queue position where the register gives one; otherwise entries printed as Gate 2 first, then every other entry by connection date. The register prints no gate for many contracted entries; N84 does not guess their position. Not published by the operator.
Table view
Cumulative MW by connection year
YearCumulative MW
2027200 MW
2028257 MW
2034349.4 MW

MW ahead in N84's order: calculator

Order calculated by N84: printed queue position where the register gives one; otherwise entries printed as Gate 2 first, then every other entry by connection date. The register prints no gate for many contracted entries; N84 does not guess their position. Not published by the operator.

Queue

Queue (calculated by N84, method n84_order_v2)
Placecalculated by N84ProjectMW (as published)MW ahead (N84 order)Connection dateGateOrder groupStatus (as printed)
1Berkswell Energy Storage200 MW0 MW31 Oct 20272gate 2Under Construction/Commissioning
2Berkswell (Tertiary)57 MW200 MW30 May 2028not statedgate not printedConsents Approved
3012 NEP Coventry West92.4 MW257 MW31 Oct 2034not statedgate not printedScoping

Receipt: MW and dates as printed in the NESO TEC Register, file dated 20 Oct 2026. Order calculated by N84: printed queue position where the register gives one; otherwise entries printed as Gate 2 first, then every other entry by connection date. The register prints no gate for many contracted entries; N84 does not guess their position. Not published by the operator. How we order

Contracted MW by effective-from year, as published
Year (MW effective from)ProjectsMW
20271200 MW
2028157 MW
2034192.4 MW

Projects recorded at this site

Projects recorded at this site, as printed
Project (as published)TechnologyMWConnection dateStatus (as printed)
Berkswell Energy StorageBattery storage200 MW31 Oct 2027Under Construction/Commissioning
012 NEP Coventry WestBattery storage92.4 MW31 Oct 2034Scoping
Berkswell (Tertiary)Hybrid57 MW30 May 2028Consents Approved

Supported by National Energy SO Open Data

Data as published by the named source on the stated date. N84 may contain matching or processing errors. Not investment, legal or technical advice. The official register prevails.